ProTankless GWH 715 ES
ProTankless GWH 715 ES
 
   
  GWH 715 ES
Power Input NG: 199,000 BTU/Hr
LP: 199,000 BTU/Hr
Maximum Flow to Activate
0.65 gallons per minute (gpm)
Flow Rates
35°F rise@ 9.2 gpm
45°F rise@ 7.3 gpm
55°F rise@ 5.9 gpm
65°F rise@ 5.0 gpm
77°F rise@ 4.2 gpm
90°F rise@ 3.6 gpm
Energy Factor*
NG: .83
LP: .83
Thermal Efficiency*
NG: 83+%
LP: 83+%
Dimensions H: 30½" W: 17.875" D: 11¼"
Weight Electronic
Modulating Gas Valve Min Firing Rate: 19,900 BTU/Hr
Max Firing Rate: 199,000 BTU/Hr
Ignition 67 lbs.
Accessories Horizontal Vent Kit (#4TWHVK3S)
Outdoor Kit (#PTOK)
[See PDF Manual]
Wireless Remote (#TSTAT2)
[See PDF Manual]
Tankless Link Cascading Kit (#TLINK)
Pipe Cover (#PTPCES)
[SEE PDF Manual]

*This information reflects the most up to date third party testing results.

GWH 715 ES Installation Specifications
Gas Connection (inches)
¾" Male NPT
Water Connections ¾" Male NPT
Inlet gas pressure under
operation (with a high hot
water flow rate)*
Propane:
8: - 13" water column
Natural Gas:
3.5" - 10.5" water column
Water Pressure Minimum: 30 PSI
(Well): 40 PSI
Maximum: 150 PSI
Electrical Supply 120V - (plugs in)
Installation Clearance Top: 12"
Front: 1"
Back: 0"
Sides: 1"
Floor: 12"
* To measure gas pressure, see Measuring Gas Pressure in your manual, chapter 3.12, page 24.

   